1.  Waters Xevo G2-XS QTof mass Spectrometer coupled with 1) ACUITY UPLC M-class with HDX technology and 2) ACUITY UPLC I-class System

Waters Xevo G2-XS QTof with ACUITY UPLC M-class HDX technology
Waters Xevo G2-XS QTof with ACUITY UPLC M-class HDX

This instrument is of high sensitivity, high resolution, and accurate mass on low volatility samples, especially organics and biomolecules. The ESI source contains an ESI sample spray and a lock spray reference for accurate mass lock mass correction. Samples are admitted to the ion source through direct infusion or UPLC. Stepwave ion guide enhances MS sensitivity (standard sample concentration 500 pg/µL, 100 fmol/µL). The QTof analyzer includes a high resolution high stability quadrupole analyzer (MS1), an XS collision cell, and a high performance Orthogonal-acceleration Time of Flight (oaTOF) mass analyzer (MS2). The optimal mass range is m/z 20 – 4000. Application examples include protein hydrogen-deuterium exchange (HDX) characterization, small molecule (e.g. pharmaceuticals, metabolites) profiling, and ESI infusion high resolution measurement of synthetic compounds. This instrument has software packages for peptide sequencing, protein characterization, and analysis HDX data.

2. Waters Quattro Micro GC

Waters Quattro Micro GC
Waters Quatro Mico GCMS

The Quattro micro GC is a tandem mass spectrometer equipped with electron ionization (EI) and chemical ionization (CI) sources for the analysis of volatile and thermally stable analyzes. Samples are introduced via a HP 6890N GC. The currently installed column is a DB-1701, 30 m × 320 mm × 1.0 mm capillary column. An Agilent 7683B autosampler is equipped to the GC inlet. The Quattro micro GC mass analyzer consists of two quadrupoles separated by a hexapole collision cell. This is often referred to as a triple quad, QQQ. Tandem quadrupoles use two stages of mass analysis, the first to pre-select an ion (the precursor ion) and the second to analyze fragments (product ions) induced by CID with an inert gas (Ar) in the collision cell. The Quattro micro GC offers the complete range of automated MS/MS CID experiments: Multiple Reaction Monitoring (MRM), Product Ion and Precursor Ion scans, and Neutral Loss/Gain. A NIST05 EI spectra library is installed with the operating software Masslynx 4.1, which allows library search of acquired EI or MS/MS spectra for compound identification. Application examples include GC-MS or GC-MS/MS of small molecules.

3. Bruker RapifleX MALDI-TOF/TOF & MALDI Imaging

Bruker RapifleX MALDI-TOF/TOF
Bruker RapifleX MALDI-TOF/TOF

The Bruker RapifleX mass spectrometer is a high resolution state-of-the-art system equipped with a Smart3D laser, a MALDI ion source, two TOF analyzer regions, a reflector, a linear detector, and a reflectron detector. Supported experiments include MALDI-TOF MS, MALDI-TOF/TOF high energy CID MS/MS, in-source decay (ISD) MS/MS, MALDI and imaging MS or MS/MS scans. The mass range is m/z 0-500 kDa. Application examples include low volatility species such as peptides, proteins, oligonucleotides, oligosaccharides, polymers, and inorganic compounds. Software packages are available for analyzing biomecolules (BioTools) and polymers (PolyTools). Please contact the Facility manager for special sample preparation requests (e.g. imaging sample preparation).

4. Thermo Scientific LTQ-Velos Orbitrap mass spectrometer coupled with an Agilent 1200 capillary LC

Thermo LTQ Velos Orbitrap
Thermo LTQ Velos Orbitrap

This instrument has a heated electrospray ionization (HESI) source. Samples are admitted to the ion source through direct infusion or LC. The mass spectrometer combines a dual-pressure linear ion trap (LTQ) with an Orbitrap analyzer, capable of high-resolution accurate mass (HRAM) measurements, m/z 50 – 2000 and 200 – 4000. Fragmentation of precursor ions is obtained by collision induced dissociation (CID). Application examples include small molecule ESI identification and quantitation by LC-HRAM or LC-MS/MS